Generator Load Bank Test Report
The only way to determine whether the generator will cope under a full load is to test your generator at its full kilowatt kw output rating.
Generator load bank test report. 6 4 4 1 1 2 specifies that the 10 second criterion does not apply during the monthly testing of the generator. A load bank test ensures that your generator will run property when it s needed so that you can fully depend on it during an emergency situation. Generally speaking you ll need to perform a weekly inspection and a monthly load test on your epss 8 4 1. The equipment used to conduct a load bank test produces artificial loads on the generator by bringing the engine to an appropriate operating temperature and pressure level.
During a generator load bank test this device verifies that all primary components of your commercial standby generator are in proper working condition and it s ready to operate as required. Load bank testing for two continuous hours each year. During this two hour period the unit should be operated as follows. In more detail the process occurs in this manner.
The generator is then step loaded with the load bank until the desired load level is reached. And every 36 months you ll need to run level 1 epss systems for the amount of time specified in your application s class up to four hours of runtime 8 4 9 1 2. Ideally the load bank should be connected to the load side of the generator breaker. At 25 of the nameplate kilowatt rating for 30 minutes.
At 50 of the nameplate kilowatt rating for 30 minutes. The emergency switchgear should be disabled to avoid accidental transfer to facility load. Any examples are for illustrative purposes only. Each step to last fifteen 15 minutes record engine and generator data as detailed later in this section.
It is also important that the load bank is situated in free air space for adequate cooling. A generator load bank test involves an examination and assessment of a genset. If a generator fails the monthly test it should be operated under a load supplied by a load bank i e. O engine exhaust temperature during test if applicable p kw load under test q identification of unsatisfactory conditions and corrective action taken including parts replaced note.
The testing for an annual load bank test and the triennial exercise may be combined according to nfpa 110 2010. After the test the technician removes the load bank load first and transfers all switches back to the normal position before allowing the generator to cool down according to manufacturer guidelines. The key to a proper load bank test is that it tests your generator at its full kilowatt kw output rating.